<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-28 21-12-46
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 57 dBuV VOLTAGE
Pilot RDS Phase Difference
6.4 kHz 3.9 kHz -7 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
12 kHz 71 kHz 10099 9,1593
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
6,1 dBr 7,16 dBr 8,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 21:12, 28.02.2025
RT
"VOLTAGE - Dance music "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (57 dBuV) Max at: 71 kHz MIN: 12 kHz % above 75 kHz: 9,1593 Acquired: 2025/02/28 21:11:42 Total samples: 10099 Equivalent time: 0:08:24 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 8,3 dBr MIN: 6,1 dBr AVE: 7,16 dBr % above 10,0 dBr: 0,0 Last value: 8,2 dBr (2025/02/28 21:11:41) Station: 96.90 MHz, signal: 4/5 (57 dBuV) 21:05 21:06 21:07 21:08 21:09 21:10 21:11 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality